It is essential for you to enter an appropriate value for the System Efficiency, and to understand what this number should and should not include. It is not calculated by Nearmap.

System Efficiency should take into account, if possible:


System Efficiency should not account for:

Panel Parameters

The panel parameters can be found in the Panels tab of the Solar tool.

Manufacturer and Model

All the panels on this list should be CEC-approved, but please verify at the CEC accreditation website as approved panels change over time. There are many CEC-approved panels that have not been added to our database yet. If your model of interest is not listed, select a similar one by the manufacturer, or just select Custom, and modify the panel parameters as you wish.

Power

Nominal power at standard test conditions. This is what the panels are capable of producing under 1000 W/m² irradiance at 25 C. It will almost always considerably exceed real-world performance.

NOCT

Nominal Operating Cell Temperature. This is the temperature that the manufacturer expects the panels to heat up to during operation in nominal operating conditions, which are 800 W/m² irradiance, 20 C, a 45 degree tilt angle, and 1 m/s wind. It is typically between 45-48 C.

Temperature Coefficient of Power

This corresponds to the percentage of power lost for each degree above 25 C the panel temperature rises.